Journal cover Journal topic
Journal of Sensors and Sensor Systems An open-access peer-reviewed journal
Journal topic

Journal metrics

Journal metrics

  • CiteScore value: 1.05 CiteScore
    1.05
  • SNIP value: 1.044 SNIP 1.044
  • SJR value: 0.289 SJR 0.289
  • IPP value: 0.85 IPP 0.85
  • h5-index value: 8 h5-index 8
  • Scimago H <br class='hide-on-tablet hide-on-mobile'>index value: 5 Scimago H
    index 5
JSSS | Articles | Volume 7, issue 2
J. Sens. Sens. Syst., 7, 559-567, 2018
https://doi.org/10.5194/jsss-7-559-2018
© Author(s) 2018. This work is distributed under
the Creative Commons Attribution 4.0 License.

Special issue: Dresden Sensor Symposium 2017

J. Sens. Sens. Syst., 7, 559-567, 2018
https://doi.org/10.5194/jsss-7-559-2018
© Author(s) 2018. This work is distributed under
the Creative Commons Attribution 4.0 License.

Regular research article 29 Oct 2018

Regular research article | 29 Oct 2018

Continuous in-line monitoring of electrolyte concentrations in extracorporeal circuits for individualization of dialysis treatment

Marc Berger et al.
Related authors  
Design and evaluation of split-ring resonators for aptamer-based biosensors
Tobias Reinecke, Johanna-Gabriela Walter, Tim Kobelt, André Ahrens, Thomas Scheper, and Stefan Zimmermann
J. Sens. Sens. Syst., 7, 101-111, https://doi.org/10.5194/jsss-7-101-2018,https://doi.org/10.5194/jsss-7-101-2018, 2018
Short summary
Electron capture detector based on a non-radioactive electron source: operating parameters vs. analytical performance
Erik Bunert, Ansgar T. Kirk, Jens Oermann, and Stefan Zimmermann
J. Sens. Sens. Syst., 6, 381-387, https://doi.org/10.5194/jsss-6-381-2017,https://doi.org/10.5194/jsss-6-381-2017, 2017
Short summary
Related subject area  
Applications: Medical
Task-specific uncertainty estimation for medical CT measurements
Judith Bredemann and Robert H. Schmitt
J. Sens. Sens. Syst., 7, 627-635, https://doi.org/10.5194/jsss-7-627-2018,https://doi.org/10.5194/jsss-7-627-2018, 2018
Short summary
The influence of intraocular pressure on the damping of a coupled speaker–air–eye system
Jan Osmers, Ágnes Patzkó, Oskar Hoppe, Michael Sorg, Axel von Freyberg, and Andreas Fischer
J. Sens. Sens. Syst., 7, 123-130, https://doi.org/10.5194/jsss-7-123-2018,https://doi.org/10.5194/jsss-7-123-2018, 2018
Short summary
Hyperspectral imaging for monitoring oxygen saturation levels during normothermic kidney perfusion
Florian Tetschke, Wenke Markgraf, Marian Gransow, Susanne Koch, Christine Thiele, Axel Kulcke, and Hagen Malberg
J. Sens. Sens. Syst., 5, 313-318, https://doi.org/10.5194/jsss-5-313-2016,https://doi.org/10.5194/jsss-5-313-2016, 2016
Short summary
Ultrafast imaging Raman spectroscopy of large-area samples without stepwise scanning
Elmar Schmälzlin, Benito Moralejo, Daniel Bodenmüller, Maxim E. Darvin, Gisela Thiede, and Martin M. Roth
J. Sens. Sens. Syst., 5, 261-271, https://doi.org/10.5194/jsss-5-261-2016,https://doi.org/10.5194/jsss-5-261-2016, 2016
Short summary
Development of a highly sensitive spectral camera for cartilage monitoring using fluorescence spectroscopy
A. Kuehn, A. Graf, U. Wenzel, S. Princz, H. Mantz, and M. Hessling
J. Sens. Sens. Syst., 4, 289-294, https://doi.org/10.5194/jsss-4-289-2015,https://doi.org/10.5194/jsss-4-289-2015, 2015
Short summary
Cited articles  
Bagshaw, S. M., George, C., and Bellomo, R.: Early acute kidney injury and sepsis: A multicentre evaluation, Crit. Care, 12, R47, https://doi.org/10.1186/cc6863, 2008. 
Baue, A. E., Faist, E., and Fry, D. E.: Multiple Organ Failure: Pathophysiology, Prevention, and Therapy, N, Springer New York, New York, 1, online resource 722, 2000. 
Bellomo, R., Kellum, J. A., and Ronco, C.: Acute kidney injury, The Lancet, 380, 756–766, https://doi.org/10.1016/S0140-6736(11)61454-2, 2012. 
Buemi, M., Aloisi, E., Coppolino, G., Loddo, S., Crascì, E., Aloisi, C., Barillà, A., Cosentini, V., Nostro, L., Caccamo, C., Floccari, F., Romeo, A., Frisina, N., and Teti, D.: The effect of two different protocols of potassium haemodiafiltration on QT dispersion, Nephrol. Dial. Transpl., 20, 1148–1154, https://doi.org/10.1093/ndt/gfh770, 2005. 
Bundesärztekammer: Richtlinie der Bundesärztekammer zur Qualitätssicherung laboratoriumsmedizinischer Untersuchungen, Deutsches Ärzteblatt, 111, A 1583–A 1618, 2014. 

Publications Copernicus
Special issue
Download
Short summary
A dialysis treatment with an individual dialysis fluid composition can prevent certain complications during treatment. For this purpose, it is necessary to know the exact electrolyte concentrations in the blood. In this work, we present a concept for continuous in-line monitoring of electrolyte concentrations using ion-selective electrodes separated from the blood flow by a dialysis membrane. First investigations of this concept show no hemolysis and a relative error of less than 0.5 %.
A dialysis treatment with an individual dialysis fluid composition can prevent certain...
Citation
Share