Articles | Volume 7, issue 1
https://doi.org/10.5194/jsss-7-123-2018
https://doi.org/10.5194/jsss-7-123-2018
Regular research article
 | 
05 Mar 2018
Regular research article |  | 05 Mar 2018

The influence of intraocular pressure on the damping of a coupled speaker–air–eye system

Jan Osmers, Ágnes Patzkó, Oskar Hoppe, Michael Sorg, Axel von Freyberg, and Andreas Fischer

Related authors

Dynamic displacement measurement of a wind turbine tower using accelerometers: tilt error compensation and validation
Clemens Jonscher, Paula Helming, David Märtins, Andreas Fischer, David Bonilla, Benedikt Hofmeister, Tanja Grießmann, and Raimund Rolfes
Wind Energ. Sci. Discuss., https://doi.org/10.5194/wes-2023-123,https://doi.org/10.5194/wes-2023-123, 2023
Revised manuscript under review for WES
Short summary
Assessing the rotor blade deformation and tower–blade tip clearance of a 3.4 MW wind turbine with terrestrial laser scanning
Paula Helming, Alex Intemann, Klaus-Peter Webersinke, Axel von Freyberg, Michael Sorg, and Andreas Fischer
Wind Energ. Sci., 8, 421–431, https://doi.org/10.5194/wes-8-421-2023,https://doi.org/10.5194/wes-8-421-2023, 2023
Short summary
Determination of the mean base circle radius of gears by optical multi-distance measurements
Marc Pillarz, Axel von Freyberg, and Andreas Fischer
J. Sens. Sens. Syst., 9, 273–282, https://doi.org/10.5194/jsss-9-273-2020,https://doi.org/10.5194/jsss-9-273-2020, 2020
Short summary

Related subject area

Applications: Medical
In-line monitoring of electrolytes and urea during continuous renal replacement therapy
Marc Berger, Merle Sehlmeyer, Flora Sellering, Hannes Röhrich, Thorsten Perl, Hussam Mansour, Daniel Baasner, and Stefan Zimmermann
J. Sens. Sens. Syst., 9, 251–262, https://doi.org/10.5194/jsss-9-251-2020,https://doi.org/10.5194/jsss-9-251-2020, 2020
Short summary
A novel non-invasive, non-conductive method for measuring respiration
Jan Ringkamp, Philipp Radler, Philipp Lebhardt, and Jens Langejürgen
J. Sens. Sens. Syst., 9, 27–32, https://doi.org/10.5194/jsss-9-27-2020,https://doi.org/10.5194/jsss-9-27-2020, 2020
Short summary
Task-specific uncertainty estimation for medical CT measurements
Judith Bredemann and Robert H. Schmitt
J. Sens. Sens. Syst., 7, 627–635, https://doi.org/10.5194/jsss-7-627-2018,https://doi.org/10.5194/jsss-7-627-2018, 2018
Short summary
Continuous in-line monitoring of electrolyte concentrations in extracorporeal circuits for individualization of dialysis treatment
Marc Berger, Michael Faulstich, Thorsten Perl, and Stefan Zimmermann
J. Sens. Sens. Syst., 7, 559–567, https://doi.org/10.5194/jsss-7-559-2018,https://doi.org/10.5194/jsss-7-559-2018, 2018
Short summary
Hyperspectral imaging for monitoring oxygen saturation levels during normothermic kidney perfusion
Florian Tetschke, Wenke Markgraf, Marian Gransow, Susanne Koch, Christine Thiele, Axel Kulcke, and Hagen Malberg
J. Sens. Sens. Syst., 5, 313–318, https://doi.org/10.5194/jsss-5-313-2016,https://doi.org/10.5194/jsss-5-313-2016, 2016
Short summary

Cited articles

Cook, J. A., Botello, A. P., Elders, A., Ali, A. F., Azuara-Blanco, A., Fraser, C., McCormack, K., and Burr, J. M.: Systematic review of the agreement of tonometers with goldmann applanation tonometry, Ophthalmology, 119, 1552–1557, https://doi.org/10.1016/j.ophtha.2012.02.030, 2012. a
Cross, R.: The bounce of a ball, Am. J. Phys., 67, 222–227, 1999. a
Derka, H.: The American Optical non-contact tonometer and its results compared to Goldmann applanation tonometry, Klin. Monatsbl. Augenh., 177, 634–642, 1980 (in German). a, b
Draeger, J.: Principles of tonometry from the time of Albrecht von Graefes to D2-mission and self-tonometry, Klin. Monatsbl. Augenh., 202, 2–7, 1993 (in German). a
Drescher, J.: Determination of the intraocular pressure from the vibration behavior of the human eye, PhD Thesis, Universität Karlsruhe, Karlsruhe, 2000 (in German). a
Download
Short summary
Glaucoma is the leading cause of irreversible blindness worldwide. The laboratory results of a novel measurement approach for the internal eye pressure are presented, with an uncertainty of less than 1 mmHg. A physical model explaining the relation between eye pressure and the damping ratio of a coupled mechanical system is defined. This provides design parameters for a handheld self-tonometer for Glaucoma diagnosis and therapeutic follow-up, with high application potential in ophthalmology.