In situ measurements of O2 and CO eq.  in cement kilns
Olga Driesner1, Fred Gumprecht1, and Ulrich Guth2 1ENOTEC GmbH, Höher Birken 6, 51709 Marienheide, Germany
2Department of Chemistry and Food Chemistry, Technische Universität Dresden, 01062 Dresden, Germany
Abstract. The simultaneous in situ measurement of O2 and CO eq.  in cement kilns is a great challenge due to the high process temperatures and high dust load. The standard method for measurement for flue gas in cement kilns is extractive. Extractive measurements have a higher response time due to the flue gas conditioning including the length of heated extraction lines for electrochemical or optical analysis. This delayed response is not optimal for fast process control.

A probe was developed for this purpose in which the in situ solid electrolyte oxygen sensor and an in situ CO eq.  mixed potential sensor are implemented. Due to the high temperatures, the probe is cooled by a water–coolant mixture. In order to prevent deposits of raw material forming and sintering on the probe, it rotates 90° in programmable intervals. In addition, an automated probe plunger pneumatically removes plugging at the probe flue gas entrance, also in programmable intervals. These self-cleaning functions allow the probe to continually stay in the process for combustion optimisation (low excess O2 and CO) and enable the plant operator to measure additional process-related gas components (NO, SO2, HCl etc.) and optimise the SNCR (selective non-catalytic reduction) for NOx reduction. Combustion air supply can be adapted very quickly due to the in situ sensors, which has been demonstrated by a CEMTEC® probe over years (Märker Cement Harburg, 2017).


Citation: Driesner, O., Gumprecht, F., and Guth, U.: In situ measurements of O2 and CO eq.  in cement kilns, J. Sens. Sens. Syst., 6, 327-330, https://doi.org/10.5194/jsss-6-327-2017, 2017.
Publications Copernicus
Special issue
Download
Share