Articles | Volume 3, issue 1
https://doi.org/10.5194/jsss-3-121-2014
https://doi.org/10.5194/jsss-3-121-2014
Regular research article
 | 
12 Jun 2014
Regular research article |  | 12 Jun 2014

Multi-channel IR sensor system for determination of oil degradation

T. Bley, E. Pignanelli, and A. Schütze

Related authors

Influence of measurement uncertainty on machine learning results demonstrated for a smart gas sensor
Tanja Dorst, Tizian Schneider, Sascha Eichstädt, and Andreas Schütze
J. Sens. Sens. Syst., 12, 45–60, https://doi.org/10.5194/jsss-12-45-2023,https://doi.org/10.5194/jsss-12-45-2023, 2023
Short summary
Influence of synchronization within a sensor network on machine learning results
Tanja Dorst, Yannick Robin, Sascha Eichstädt, Andreas Schütze, and Tizian Schneider
J. Sens. Sens. Syst., 10, 233–245, https://doi.org/10.5194/jsss-10-233-2021,https://doi.org/10.5194/jsss-10-233-2021, 2021
Short summary
Random gas mixtures for efficient gas sensor calibration
Tobias Baur, Manuel Bastuck, Caroline Schultealbert, Tilman Sauerwald, and Andreas Schütze
J. Sens. Sens. Syst., 9, 411–424, https://doi.org/10.5194/jsss-9-411-2020,https://doi.org/10.5194/jsss-9-411-2020, 2020
Short summary
Siloxane treatment of metal oxide semiconductor gas sensors in temperature-cycled operation – sensitivity and selectivity
Caroline Schultealbert, Iklim Uzun, Tobias Baur, Tilman Sauerwald, and Andreas Schütze
J. Sens. Sens. Syst., 9, 283–292, https://doi.org/10.5194/jsss-9-283-2020,https://doi.org/10.5194/jsss-9-283-2020, 2020
Short summary
Enabling a new method of dynamic field-effect gas sensor operation through lithium-doped tungsten oxide
Marius Rodner, Manuel Bastuck, Andreas Schütze, Mike Andersson, Joni Huotari, Jarkko Puustinen, Jyrki Lappalainen, and Tilman Sauerwald
J. Sens. Sens. Syst., 8, 261–267, https://doi.org/10.5194/jsss-8-261-2019,https://doi.org/10.5194/jsss-8-261-2019, 2019
Short summary

Related subject area

Sensor principles and phenomena: Optical and infrared sensors
Investigation of the degree of cross-linking of polyethylene and thermosets using absolute optical spectroscopy and Raman microscopy
Florian Bergmann, Norbert Halmen, Claudia Scalfi-Happ, Dominik Reitzle, Alwin Kienle, Linda Mittelberg, Benjamin Baudrit, Thomas Hochrein, and Martin Bastian
J. Sens. Sens. Syst., 12, 175–185, https://doi.org/10.5194/jsss-12-175-2023,https://doi.org/10.5194/jsss-12-175-2023, 2023
Short summary
Compact silicon-based attenuated total reflection (ATR) sensor module for liquid analysis
Armin Lambrecht, Carsten Bolwien, Hendrik Fuhr, Gerd Sulz, Annett Isserstedt-Trinke, André Magi, Steffen Biermann, and Jürgen Wöllenstein
J. Sens. Sens. Syst., 12, 123–131, https://doi.org/10.5194/jsss-12-123-2023,https://doi.org/10.5194/jsss-12-123-2023, 2023
Short summary
Real-time active-gas imaging of small gas leaks
Max Bergau, Thomas Strahl, Benjamin Scherer, and Jürgen Wöllenstein
J. Sens. Sens. Syst., 12, 61–68, https://doi.org/10.5194/jsss-12-61-2023,https://doi.org/10.5194/jsss-12-61-2023, 2023
Short summary
Non-invasive blood sugar detection by cost-effective capacitance spectroscopy
Shazzad Rassel, Md Rejvi Kaysir, Abdulrahman Aloraynan, and Dayan Ban
J. Sens. Sens. Syst., 12, 21–36, https://doi.org/10.5194/jsss-12-21-2023,https://doi.org/10.5194/jsss-12-21-2023, 2023
Short summary
Resonant photoacoustic cells for laser-based methane detection
Katrin Schmitt, Mara Sendelbach, Christian Weber, Jürgen Wöllenstein, and Thomas Strahl
J. Sens. Sens. Syst., 12, 37–44, https://doi.org/10.5194/jsss-12-37-2023,https://doi.org/10.5194/jsss-12-37-2023, 2023
Short summary

Cited articles

Agoston, A., Ötsch, C., Zhuravleva, J., and Jakoby, B.: An IR-Absorption Sensor System for the Determination of Engine Oil Deterioration, Proceedings of IEEE Sensors Conference, 463–466, https://doi.org/10.1109/ICSENS.2004.1426200, 2004.
Agoston, A., Schneidhofer, C., Dörr, N., and Jakoby, B.: A concept of an infrared sensor system for oil condition monitoring, e & i Elektrotechnik und Informationstechnik, 125/3, 71–75, https://doi.org/10.1007/s00502-008-0506-3, 2008.
ASTM International: Standard Practice for Condition Monitoring of Used Lubricants by Trend Analysis Using Fourier Transform Infrared (FT-IR) Spectrometry, ASTM International, E2412-04, 2007.
ASTM International: Standard Specification for Reagent Water, ASTM International, D1193-06, 2011a.
ASTM International: Standard Test Method for Acid and Base Number by Color-Indicator Titration, ASTM International, D974-11, 2011b.