Articles | Volume 2, issue 2
https://doi.org/10.5194/jsss-2-157-2013
https://doi.org/10.5194/jsss-2-157-2013
Regular research article
 | 
24 Sep 2013
Regular research article |  | 24 Sep 2013

Novel fully-integrated biosensor for endotoxin detection via polymyxin B immobilization onto gold electrodes

A. Zuzuarregui, S. Arana, E. Pérez-Lorenzo, S. Sánchez-Gómez, G. Martínez de Tejada, and M. Mujika

Related subject area

Sensor principles and phenomena: Chemical and biochemical sensors
Design of a dual electrochemical quartz crystal microbalance with dissipation monitoring
Rafael Ecker, Nikolaus Doppelhammer, Bernhard Jakoby, and Erwin Konrad Reichel
J. Sens. Sens. Syst., 11, 21–28, https://doi.org/10.5194/jsss-11-21-2022,https://doi.org/10.5194/jsss-11-21-2022, 2022
Short summary
Surface plasmon assisted toxic chemical NO2 gas sensor by Au ∕ ZnO functional thin films
Ravinder Gaur, Himanshu Mohan Padhy, and Manikandan Elayaperumal
J. Sens. Sens. Syst., 10, 163–169, https://doi.org/10.5194/jsss-10-163-2021,https://doi.org/10.5194/jsss-10-163-2021, 2021
Short summary
Studies on porosity in poly(N-isopropylacrylamide) hydrogels for fast-responsive piezoresistive microsensors
Daniela Franke and Gerald Gerlach
J. Sens. Sens. Syst., 10, 93–100, https://doi.org/10.5194/jsss-10-93-2021,https://doi.org/10.5194/jsss-10-93-2021, 2021
Ceramic multilayer technology as a platform for miniaturized sensor arrays for water analysis
Claudia Feller and Uwe Partsch
J. Sens. Sens. Syst., 10, 83–91, https://doi.org/10.5194/jsss-10-83-2021,https://doi.org/10.5194/jsss-10-83-2021, 2021
Short summary
Glass electrode half-cells for measuring unified pH in ethanol–water mixtures
Agnes Heering, Frank Bastkowski, and Steffen Seitz
J. Sens. Sens. Syst., 9, 383–389, https://doi.org/10.5194/jsss-9-383-2020,https://doi.org/10.5194/jsss-9-383-2020, 2020
Short summary

Cited articles

Annane, D., Bellissant, E., and Cavaillon, J.-M.: Septic shock, Lancet, 365, 63–78, https://doi.org/10.1016/S0140-6736(04)17667-8, 2005.
Añorga, L. and Arana, S.: G01N27/407D2. Patent: Pseudo-electrodo de referencia de película delgada y procedimiento para su fabricación, WO/2011/054982, 1, 2011.
Ansorena, P., Zuzuarregui, A., Pérez-Lorenzo, E., Mujika, M., and Arana, S.: Comparative analysis of QCM and SPR techniques for the optimization of immobilization sequences, Sensor. Actuat. B-Chem., 155, 667–672, 2011.
Berganza, J., Olabarria, G., García, R., Verdoy, D., Rebollo, A., and Arana, S.: DNA microdevice for electrochemical detection of Escherichia coli 0157:H7 molecular markers, Biosens. Bioelectron., 22, 2132–2137, https://doi.org/10.1016/j.bios.2006.09.028, 2007.
Bonroy, K., Friedt, J.-M., Frederix, F., Laureyn, W., Langerock, S., Campitelli, A., Sára, M., Borghs, G., Goddeeris, B., and Declerck, P.: Realization and characterization of porous gold for increased protein coverage on acoustic sensors, Anal. Chem., 76, 4299–306, https://doi.org/10.1021/ac049893u, 2004.